Project objective:
Provide experience with computer aided air conditioning load estimation and system selection and then submit a report.
With given floor plan, do cooling load calculation for the area assigned and analysis of load profile. Comparative study of the energy performance of the system is needed in the selection process. Then determine which air appropriate all-air system to use (CAV or VAV)
Compute the air conditioning load using Carrier E-20 II software.
Analysis should include in the report:
1) Division of assigned areas into zones and load profile of each zone analysed
2) Selection of appropriate all air system( cav or vav) for the assigned area
Justification to be presented in report based upon energy performance of system
3)Justification for the assumptions made in analysis and values selected for input file shall be given in report
4) calculations for equipment selection shall be shown in report
If you are familiar with the software Carrier E20 II and Hourly Analysis Program, do apply for this project. Will send you floor plan if you're familiar.
Hi,
Im a mechanical engineer and specialized in MEP design. I did lot of HVAC calculation project. i can do your project sa you wish. Also we can negotiate project cost according to the work capacity.
Thank You.
Hi,
Let handle your works to professionals. I am an engineer and expert in the field. I can guarantee 100% accuracy and quick completion. You can view my reviews to assure quality of my works. Hope to hear you from soon.
Thank You.
I am very familiar with carrier hap software package. I have done many heat loads and simulations using this package, however i prefer the design builder and revit heat load and simulation packages. As an illustration i can provide you results from all 3 packages which will also be in the form of a 3d drawing. HAP has shortcomings
I have 12 years experience in HVAC design and drafting, I started using E-20 since it was under DOS and till now so i have very good experience with that
Several HVAC&R projects developed during my 7 years mechanical engineer's career, dx and chilled water systems up to 500 TR for malls, auditoriums, hospitals (including surgery rooms), small hotels.
i am a senior Mechanical Engineer, specialized at HVAC.
I have done a lot of HAP & Elite Load Analysis for variety of projects: Housing, Industrial, Offices, Stadiums, Hospitals & Academic.
I'm a mechanical engineer and have a good experience in thermal charge calculus, choose cooling systems for shoppings and companies. I hope that you can choose me for job.
I have complete expertise is HVAC consultancy and I can design an energy optimized system for you. Usually I use Trace Load 700 and Autocad for my calculations and design. Can use Carrier E-20 but prefer Trace Load.
Send me the floor plans and contact me on skype : mobeen7111 so that we can discuss is further detail.